Digital Signal Processor

Digital Signal Processor

Product Details:

X

Product Description

Digital Signal Processor:


A digital signal processor (DSP) and a VLSI component form the basis of the controller's technology. It features an LCD display, analog and digital circuitry, precise firing algorithms and optional communication capabilities. The controller has 9 input channels; 4 voltages (for Wye networks), 3 main currents and 2 internal system currents. The information obtained from these measurements is used for Fast Fourier Transform (FFT) analysis, performed each network cycle on all channels. Further harmonics are calculated on all phases, allowing the Activcomp to achieve ideal compensation even in the presence of harmonics.

The Activcomp's controller is available with a choice of data gathering levels, from essential power parameter measurements only (V, I, f, kW, kVA, kVAr) to complete power system performance monitoring that takes advantage of the comprehensive measurement system (over 2,000 electrical parameters, including min/max levels and four-quadrant measurement of power and power factor).

The large LCD display is full-graphic, 160x128 pixels, and has long-lasting LED back lighting with FSTN technology. Characters are displayed in varying sizes and methods to enhance visibility. These include a Large Digits display, Harmonic spectrum, real-time Waveform plots and simple Text screens that include menus, easy-to-use setup programs and various measurements.

General Specifications:

Operational Mode:

  • Manual
  • Automatic
  • Test

Scan mode:

Display Structure:

  • Graphic, high contrast FSTN LCD
  • 4.7", Black/White
  • Long life LED back light
  • Anti glare coated polycarbonate window
Controller Specifications:

Power Supply 115/230V, 50/60Hz
LCD Display Size 94 x 76mm
LCD Display Resolution Graphic 160 x 128 pixels
LCD Display Type FSTN, LED back light
Frequency 30 to 70 Hz
Power Consumption 10VA
Operating temperature 20 to +65°C
Communications RS-485 communication port
Alarm
Voltage free N.O/N.C, relay, max 2A@250VAC
Protection class IP 40
Dimensions 144 x 144 x 138 mm

Functions:
  • Menu driven operation
  • Self explained windows
  • User friendly
  • Easy installation using
Display Modes (Refer to images on next page):
  • Large digit screen - displays 9 numerical values.
  • Waveform screen - displays wave shape together with waveform detailed information.
  • Harmonics screen - displays complete harmonic spectrum, including each harmonic details from 1st to 63rd (amplitude, percentage and phase shift).
Built in Power Quality Measurement System Simultaneous Measurement of the following sections:
  • Mains (total of load and capacitor)
  • Load
  • Capacitor (system)
  • Combination of Mains, Load and Capacitors
For example, if reactive energy parameter is selected, the user can see the KVAr consumption by the Load, the connected KVAr by the Capacitor System and the resulton the Mains.

Calculation Method:
  • True RMS measurements (upto 63rd harmonics).
  • Based on FFT algorithm which is carried out cycle to cycle (128 samples per cycle).
Error & Alarms:
  • Self explained, automatic capacitor groupself test procedure.
  • Blown fuse error.
  • Shorted SCR error.
  • Over temperature alarm.
  • Parallel resonance detection mechanism.
The system identifies the resonance frequency (5th, 7th etc.) and disables the connection of the capacitors groups as soon as resonance occurs.

Communication:
  • Isolated RS485.
  • Upto 115k Baud Rate.
  • Protocols options: ELCOM - (High Speed Communication protocol) ModBus/RTU (IEEE 754 Floating Point).
Measured Parameters in Activcomp Controller:

Parameters
Phases
Loads
Measurement
Frequency
Common
Mains

Phase Current
L1, L2, L3
Mains, Load, Cap.

Neutral Current
Neutral
Mains

Phase to Phase Current
L1-2, L2-3, L3-1
Mains, Load

Phase Voltage
L1, L2, L3
Mains

Neutral Voltage
Neutral
Mains

Phase to Phase Voltage
L1-2, L2-3, L3-1
Mains

Active Power (kW)
L1, L2, L3, Total
Mains

Reactive Power (kVAr)
L1, L2, L3, Total
Mains, Load, Cap.

Apparent Power (kVA)
L1, L2, L3, Total Mains, Load, Cap.

Power Factor
L1, L2, L3, Total Mains, Load, Cap.

Time of use (TOU) - in, out, net, total


Active Energy (kWh) Total Mains

Reactive Energy (kVARh) Total Mains

THD at Phase Current
L1, L2, L3
Mains, Load, Cap.

THD at Neutral Current
Neutral
Mains

THD at Phase to Phase Current
L1-2, L2-3, L3-1
Mains, Load

THD at Phase Voltage
L1, L2, L3
Mains

THD at Phase to Phase Voltage
L1-2, L2-3, L3-1
Mains

Harmonics of Phase Current
L1, L2, L3
Mains, Load, Cap.

Harmonics of Neutral Current
Neutral
Mains

Harmonics of Phase to Phase Current
L1-2, L2-3, L3-1
Mains, Load

Harmonics of Phase Voltage
L1, L2, L3
Mains

Harmonics of Neutral Voltage
Neutral
Mains

Harmonics of Phase to Phase Voltage
L1-2, L2-3, L3-1
Mains

Waveforms of Phase Current
L1, L2, L3
Mains, Load, Cap.

Waveforms of Neutral Current
Neutral
Mains

Waveforms of Phase of Phase Current
L1-2, L2-3, L3-1
Mains

Waveforms of Phase Voltage
L1, L2, L3
Mains

Waveforms of Neutral Voltage
Neutral
Mains

Waveforms of Phase to Phase Voltage
L1-2, L2-3, L3-1
Mains

System Log
Event Log